MRO Auction - Industrial Equipment & Robotics. MRO Auction Timed Online Auction Ended Jun 13, 2013 11:02am CDT (5:02pm BST). JETLINE ENGINEERING SERIES 9600 CONTROL 9627. More details. Timed Auction; Location: Warren, Michigan. JETLINE ENGINEERING AFS-3-13 CONTROL. Act 1974, Control of Substances Hazardous to Health Regulations 2002 or any other current legislations covering the use of such substances in a working environment in the United States or any other relevant jurisdiction. Buyers acknowledge that an auction site is. 1000x user manual, avent dampfgarer bedienungsanleitung, 2009 subaru forester 25x premium and owners manual, gl622 user manual, 1990 ford laser workshop manual pdf, jetline engineering series 9600 control user manual, montero sport 2012 owners manual pdf, daihatsu terios owners manual free download, bmw.
12 A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures
Product/Technical Bulletin
Product/Technical Bulletin
Technical Specifications
Product A419 Series Electronic Temperature Controls with NEMA 1 General Purpose or NEMA 4X
Watertight, Corrosion-Resistant Enclosures
Setpoint Range -30 to 212°F (-34 to 100°C)
Differential Range 1 to 30F° (1 to 30C°)
Supply Voltage 24 VAC, 60 Hz, Class 2:
A419GBF-1 (NEMA 1 Enclosure Model)
A419GEF-1 (NEMA 4X Watertight Enclosure Model)
120 or 240 VAC, 60 Hz:
A419ABC-1 (NEMA 1 Enclosure Model)
A419AEC-1 (NEMA 4X Watertight Enclosure Model)
Power Consumption 1.8 VA Maximum
Output Relay Contacts
Electrical Ratings
24 VAC Models:
A419GBF-1 (NEMA 1 Enclosure)
A419GEF-1 (NEMA 4X Watertight Enclosure)
100 VA, 30 VAC maximum, Class 2
120/240 VAC Models:
A419ABC-1 (NEMA 1 Enclosure)
Jetline Engineering Series 9600 Control User Manual Instructions
A419AEC-1 (NEMA 4X Watertight Enclosure)
Applied Voltage:
120 VAC
208 VAC
240 VAC
Horsepower N.O. (N.C.) :
1 (0.25) hp
1 (0.33) hp
1 (0.5) hp
Full Load Amperes N.O. (N.C.):
16 (5.8) A
9.2 (4.0) A
8.0 (4.9) A
Locked Rotor Amperes N.O. (N.C.):
96 (34.8) A
55.2 (24) A
48 (29.4) A
Non-inductive Amperes N.O. (N.C.):
15 (10) A
10 (10) A
10 (10) A
Pilot Duty:
125 VA (N.O. contacts) at 24 to 240 VAC
125 VA (N.C. contacts) at 120 to 240 VAC
50 VA (N.C. contacts) at 24 VAC
Sensor Type A99BB Type PTC Sensor (See Table 6)
Control Ambient
Temperature
Operating:
-26 to 140°F (-32 to 60°C)
Shipping:
-40 to 185°F (-40 to 85°C)
Ambient Humidity 0 to 95% RH Non-condensing; Maximum Dew Point: 85°F (29°C)
Control Material Case and Cover:
NEMA 1 High-Impact Thermoplastic
NEMA 4X Watertight, Corrosion-Resistant, High-Impact
Thermoplastic Polycarbonate
Agency Listings UL: File E27734; CCN’s XAPX (US), XAPX7 (Canada)
FCC: CFR 47, Part 15, Class A. DOC, Class A
Building Efficiency
507 E. Michigan Street, Milwaukee, WI 53202
® Johnson Controls and PENN are registered trademarks of Johnson Controls, Inc. in the
United States of America and/or other countries. Stihl 034 av repair manual download. All other trademarks used herein are the property
of their respective owners. © Copyright 2014 by Johnson Controls, Inc. All rights reserved.
Advertising
Popular Brands
Popular manuals